  • If this is your first visit, be sure to check out the Welcome Post and the FAQ . In order to reply to a post or start a new thread, you will need to register : click the Register link above to proceed. To start viewing messages, select the forum that you want to visit from the selections below. Make sure to read the Terms of Use before using the Lutron Support Community Forums.

Thanks

Thread: Old Homework’s interactive

Thread tools.

  • Show Printable Version

Search Thread

  •   Advanced Search
  • View Profile
  • View Forum Posts
  • Private Message

tankie is offline

My system was installed in 2002 and I purchased My home In 2006. My system is basic with only lights and fan controls. I replaced some incandescent CBR 30 s with CFL R 30 dimmable Over last 10 years with no problems as they were Compatible. CFL s are getting scarce so I started replacing with dimmable led s made lay Sunco Now they want stay on but 5 minutes or so and go off and I have to keep turning them back on In an effort to overcome this I replaced all my kitchen bulbs with original incandescents but they Still go off after 5 minutes. I have 6 Sunco dimmable leds in my pantry and they stay on with no problem. My lutron touch pads are HWI-KP-LB6 and the kitchen circuit is back to back with the pantry circuit. I interchanged the touch pads and kitchen circuit still goes off after 5 minutes but the pantry stays on so the touch pads are ok. This leaves the problem in my control modules in the basement utilities room. I reinstalled my staircase lamps with incandescent and they also only stay on around 5 minutes or so then go off I have 28 drivers including two fan drivers. There’s 7 drivers in each module cabinet. My HWI-MI -120 processor is located in cabinet Module one and has a manual over switch. I can hit the override switch and every light in the entire house comes on and stays on. When I turn on a circuit with the Sunco led R 30 s The bulbs make a crinkle noise as they heat up then go off after 5 minutes. My garage touchpad circuit has 18 double 4 foot flouresent strips and they all stay on with no problems. I have touch pad controled flouresent strips under my kitchen cabinets that have no problems It’s impossible to convert my home to standard 120 volt switches Does anyone have any trouble shooting I can perform.

randyc is offline

The "touch pads" (LB6) are low voltage keypads and don't directly control electricity flowing to the lights. Keypad issues would be a stuck button or the keypad was damaged by a surge. You can test this by turning the lights on and removing the keypad. When you turn the override on, it turns on every load in the system (very common practice). Your system has a vacation mode. It records the status of the lights and plays it back with some randomization. There should be a button on a keypad to turn vacation mode off. You can try rebooting the processor but it may be programmed to restart vacation mode. The vacation database could be corrupted. This could make it do weird things like turning lights off after 5 minutes. I would try a brand name LED. Philips or Cree. They cost a more but are worth it. Most power companies have rebate programs - either through retailers or via reimbursement. Some less expensive LED drivers emit RF noise. The noise increases exponentially with each fixture. We now try to limit the number of LEDs to 10 or so to minimize this. You may also be experiencing an issue with minimum loads. The remote modules typically have a minimum of 10 watts. You may actually need more because of the age of the system and the use of LEDs. If your system is connected to another system (Crestron, etc.), disconnect the cable and test the lights. Since all of the lights are run to the basement panels, it would be virtually impossible to reroute them back to local switches. Keep in mind that this is a 17 year old computer system. With some fine tuning it can be a good system again.
Convergence Technologies Raleigh, North Carolina www.convergenceusa.com
I just purchase 16 HD-RPM-4 U 120 used modules but came out of a working system I thinking maybe my modules are damaged by the Led bulbs so I plan to swap the kitchen module To see if the kitchen circuit stays on I was instructed to match the address dial number (1 through 6) with the modules I am replacing I have already switched the kitchen lights back to Incandescents that still only stay on 5 minutes or so If this doesn’t work i can hopefully eliminate the modules as being the problem You mentioned the vacation mode could be the problem. How do I check and reset the vacation mode Also the pantry leds that stays on are on their own 15 amp breaker and maybe not wired to a module I have basic electrical knowledge so some of these issues are over my head I also swapped my staircase led s back to incandescent (6) and they still only stay on about 5 minutes I have two rooms that have MR 16 halogen ( 12) in valances that stay on with no problem I am open to any suggestions to fix my problems Thanks My cell phone is 239 872 6950
  • Private Messages
  • Subscriptions
  • Who's Online
  • Search Forums
  • Forums Home
  • Welcome to the Lutron Support Community
  • General Discussion - HWQSX
  • Troubleshooting - HWQSX
  • Design Assistance - HWQSX
  • Programming - HWQSX
  • 3rd-party Integration - HWQSX
  • Best Practices - HWQSX
  • General Discussion - RA3
  • Troubleshooting - RA3
  • Design Assistance - RA
  • Programming - RA3
  • 3rd-party Integration - RA3
  • Best Practices - RA3
  • General Discussion - RA2
  • Troubleshooting - RA2
  • Design Assistance - RA2
  • Programming - RA2
  • 3rd-party Integration - RA2
  • Best Practices - RA2
  • General Discussion - CAS
  • Troubleshooting - CAS
  • Design Assistance - CAS
  • Programming - CAS
  • 3rd-party Integration - CAS
  • Best Practices - CAS
  • General Discussion - Shades
  • Troubleshooting - Shades
  • Design Assistance - Shades
  • Programming - Shades
  • 3rd-party Integration - Shades
  • Best Practices - Shades
  • General Discussion - LED
  • Performance Issues - LED
  • Compatibility - LED
  • Lutron Hi-Performance LED Driver - LED
  • General Discussion - Quantum
  • Troubleshooting - Quantum
  • Design Assistance - Quantum
  • Programming - Quantum
  • 3rd-party Integration - Quantum
  • Best Practices - Quantum
  • General Discussion - Vive
  • Troubleshooting - Vive
  • Design Assistance - Vive
  • Programming - Vive
  • 3rd-party Integration - Vive
  • Best Practices - Vive
  • General Discussion - Standalone ETP
  • Programming - Standalone ETP
  • Troubleshooting - Standalone ETP
  • Design Assistance - Standalone ETP
  • 3rd Party Integration - Standalone ETP
  • Best Practices - Standalone ETP
  • General Discussion - General Commercial
  • Troubleshooting - General Commercial
  • Design Assistance - General Commercial
  • Programming - General Commercial
  • 3rd Party Integration - General Commercial
  • Best Practices - General Commercial
  • General Discussion - Controls
  • Troubleshooting - Controls
  • Design Assistance - Controls
  • Programming - Controls
  • 3rd-party Integration - Controls
  • Best Practices - Controls
  • General Discussion - HWQS
  • Troubleshooting - HWQS
  • Design Assistance - HWQS
  • Programming - HWQS
  • 3rd-party Integration - HWQS
  • Best Practices - HWQS
  • General Discussion - Legacy HW
  • Design Assistance - Legacy HW
  • Programming - Legacy HW
  • 3rd-party Integration - Legacy HW
  • Best Practices - Legacy HW
  • General Discussion - Legacy RA
  • Troubleshooting - Legacy RA
  • Programming - Legacy RA
  • 3rd-party Integration - Legacy RA
  • Best Practices - Legacy RA
  • General Discussion - Legacy QED
  • Troubleshooting - Legacy QED
  • Programming - Legacy QED
  • 3rd Party Integration - Legacy QED
  • Best Practices - Legacy QED
  • General Discussion - Legacy Other
  • Troubleshooting - Legacy Other
  • Programming - Legacy Other
  • 3rd Party Integration - Legacy Other
  • Best Practices - Legacy Other

Similar Threads

Interactive to qs, interactive to illumination processors, homeworks interactive, is an upgrade of interactive to qs possible, posting permissions.

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is Off
  • HTML code is Off

Forum Rules

  • Lutron Support Community

This website may contain user-submitted content and is for informational use only. Lutron disclaims any and all liability for the accuracy and correctness of content and conduct of any third parties in connection with or related to your use of the site. Please see the Terms of Use for more information.

Privacy Policy

(c) 2014 Lutron Electronics Co., Inc.

  • Скидки дня
  • Справка и помощь
  • Адрес доставки Идет загрузка... Ошибка: повторите попытку ОК
  • Продажи
  • Список отслеживания Развернуть список отслеживаемых товаров Идет загрузка... Войдите в систему , чтобы просмотреть свои сведения о пользователе
  • Краткий обзор
  • Недавно просмотренные
  • Ставки/предложения
  • Список отслеживания
  • История покупок
  • Купить опять
  • Объявления о товарах
  • Сохраненные запросы поиска
  • Сохраненные продавцы
  • Сообщения
  • Уведомление
  • Развернуть корзину Идет загрузка... Произошла ошибка. Чтобы узнать подробнее, посмотрите корзину.

Oops! Looks like we're having trouble connecting to our server.

Refresh your browser window to try again.

Tupolev TU-144

  • Read more about CCCP-77112

Crash of a Tupolev TU-144D in Kladkovo: 2 killed

lutron homeworks hwi mi 120

Crash of a Tupolev TU-144S in Goussainville: 14 killed

lutron homeworks hwi mi 120

DB-City

  • Bahasa Indonesia
  • Eastern Europe
  • Moscow Oblast

Elektrostal

Elektrostal Localisation : Country Russia , Oblast Moscow Oblast . Available Information : Geographical coordinates , Population, Area, Altitude, Weather and Hotel . Nearby cities and villages : Noginsk , Pavlovsky Posad and Staraya Kupavna .

Information

Find all the information of Elektrostal or click on the section of your choice in the left menu.

  • Update data
Country
Oblast

Elektrostal Demography

Information on the people and the population of Elektrostal.

Elektrostal Population157,409 inhabitants
Elektrostal Population Density3,179.3 /km² (8,234.4 /sq mi)

Elektrostal Geography

Geographic Information regarding City of Elektrostal .

Elektrostal Geographical coordinatesLatitude: , Longitude:
55° 48′ 0″ North, 38° 27′ 0″ East
Elektrostal Area4,951 hectares
49.51 km² (19.12 sq mi)
Elektrostal Altitude164 m (538 ft)
Elektrostal ClimateHumid continental climate (Köppen climate classification: Dfb)

Elektrostal Distance

Distance (in kilometers) between Elektrostal and the biggest cities of Russia.

Elektrostal Map

Locate simply the city of Elektrostal through the card, map and satellite image of the city.

Elektrostal Nearby cities and villages

Elektrostal Weather

Weather forecast for the next coming days and current time of Elektrostal.

Elektrostal Sunrise and sunset

Find below the times of sunrise and sunset calculated 7 days to Elektrostal.

DaySunrise and sunsetTwilightNautical twilightAstronomical twilight
23 June02:41 - 11:28 - 20:1501:40 - 21:1701:00 - 01:00 01:00 - 01:00
24 June02:41 - 11:28 - 20:1501:40 - 21:1601:00 - 01:00 01:00 - 01:00
25 June02:42 - 11:28 - 20:1501:41 - 21:1601:00 - 01:00 01:00 - 01:00
26 June02:42 - 11:29 - 20:1501:41 - 21:1601:00 - 01:00 01:00 - 01:00
27 June02:43 - 11:29 - 20:1501:42 - 21:1601:00 - 01:00 01:00 - 01:00
28 June02:44 - 11:29 - 20:1401:43 - 21:1501:00 - 01:00 01:00 - 01:00
29 June02:44 - 11:29 - 20:1401:44 - 21:1501:00 - 01:00 01:00 - 01:00

Elektrostal Hotel

Our team has selected for you a list of hotel in Elektrostal classified by value for money. Book your hotel room at the best price.



Located next to Noginskoye Highway in Electrostal, Apelsin Hotel offers comfortable rooms with free Wi-Fi. Free parking is available. The elegant rooms are air conditioned and feature a flat-screen satellite TV and fridge...
from


Located in the green area Yamskiye Woods, 5 km from Elektrostal city centre, this hotel features a sauna and a restaurant. It offers rooms with a kitchen...
from


Ekotel Bogorodsk Hotel is located in a picturesque park near Chernogolovsky Pond. It features an indoor swimming pool and a wellness centre. Free Wi-Fi and private parking are provided...
from


Surrounded by 420,000 m² of parkland and overlooking Kovershi Lake, this hotel outside Moscow offers spa and fitness facilities, and a private beach area with volleyball court and loungers...
from


Surrounded by green parklands, this hotel in the Moscow region features 2 restaurants, a bowling alley with bar, and several spa and fitness facilities. Moscow Ring Road is 17 km away...
from

Elektrostal Nearby

Below is a list of activities and point of interest in Elektrostal and its surroundings.

Elektrostal Page

Direct link
DB-City.comElektrostal /5 (2021-10-07 13:22:50)

Russia Flag

  • Information /Russian-Federation--Moscow-Oblast--Elektrostal#info
  • Demography /Russian-Federation--Moscow-Oblast--Elektrostal#demo
  • Geography /Russian-Federation--Moscow-Oblast--Elektrostal#geo
  • Distance /Russian-Federation--Moscow-Oblast--Elektrostal#dist1
  • Map /Russian-Federation--Moscow-Oblast--Elektrostal#map
  • Nearby cities and villages /Russian-Federation--Moscow-Oblast--Elektrostal#dist2
  • Weather /Russian-Federation--Moscow-Oblast--Elektrostal#weather
  • Sunrise and sunset /Russian-Federation--Moscow-Oblast--Elektrostal#sun
  • Hotel /Russian-Federation--Moscow-Oblast--Elektrostal#hotel
  • Nearby /Russian-Federation--Moscow-Oblast--Elektrostal#around
  • Page /Russian-Federation--Moscow-Oblast--Elektrostal#page
  • Terms of Use
  • Copyright © 2024 DB-City - All rights reserved
  • Change Ad Consent Do not sell my data

Cybo The Global Business Directory

  • Moscow Oblast
  •  » 
  • Elektrostal

State Housing Inspectorate of the Moscow Region

Phone 8 (496) 575-02-20 8 (496) 575-02-20

Phone 8 (496) 511-20-80 8 (496) 511-20-80

Public administration near State Housing Inspectorate of the Moscow Region

JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.

  • Create an Account

ACE Systems

  • Compare Products

LUTRON HWI-MI-120

New Model/Open Box

Works with QS, HW and HWI models.

LUTRON   HWI-MI-120

New QS Compatible Model.

60 Day Warranty  

For Questions Call:

ACE Systems

770-781-4650

More Information
Condition New

IMAGES

  1. Lutron hwi-mi-120 homeworks interactivo módulo interfaz montaje 120 V

    lutron homeworks hwi mi 120

  2. LUTRON Homeworks Interactive HWI-MI-120

    lutron homeworks hwi mi 120

  3. Lutron HomeWorks Interactive HWI-MI-120 Module With Cable L446

    lutron homeworks hwi mi 120

  4. Lutron HomeWorks HWI-MI-120

    lutron homeworks hwi mi 120

  5. Lutron HomeWorks Interactive HWI-MI-120 Module With Cable L446

    lutron homeworks hwi mi 120

  6. LUTRON HWI-MI-120 Homeworks and QS Compatible

    lutron homeworks hwi mi 120

VIDEO

  1. BPP University: Study at BPP University in UK

  2. Juri vs M.Bison.mp4

  3. Me when homework:

  4. Lutron QED Shades up in unison

  5. How to enable 120 FPS in IQOO NEO 9 Pro 120 FPS not showing BGMI l IQOO NEO 9 Pro 120 FPS no showing

  6. why are you like this ?? ft squid!

COMMENTS

  1. PDF HWI-MI-120 HomeWorks Interactive Module Installation Instructions

    4. Set Enclosure Address. Set the rotary switch on the module interface to the address assigned in the HomeWorks Interactive Utility. 5. Connect Communication Wiring. Connect the control wiring to the processor communication link terminal block on the lower end of the module interface board. See Figure 3.

  2. PDF HomeWorks Module Interface

    www.lutron.com Lutron ® | 1. product specifications 369-545a. 06.22.12. HomeWorks ® Module Interface. Module Interface (HWI-MI-120) A Module Interface controls up to eight . Remote Power Modules (RPMs) in a remote power panel enclosure. The Module Interface manages communication between the RPMs and a processor. A Module Interface is powered

  3. PDF HWI-MI-120 TM HomeWorks InteractiveTM Module Installation Instructions

    HWI-MI-120 HomeWorks ® Interactive TM Module Interface Assembly This product may be covered under one or more of the following U.S. patents: 4,797,599; 4,889,999; 5,170,068; 5,237,207 and corresponding foreign patents. U.S. and foreign patents pending. Lutron and HomeWorks are registered trademarks and

  4. PDF Module Interface

    El # hWI-MI-120)A stand-alone module interface controls up to eight RPMs in a remote power panel enclosure that does not con. ain a processor. In this configuration, the module interface manages communication between the RPMs and a wired processor located in a se. arate enclosure. A stand-alone module interface derives power from its own ...

  5. PDF Solutions for Upgrading from HomeWorks Illumination to HomeWorks QS

    120 - 240 V Input / Entrada / Entrée 24 V Output / Salida / Sortie 22.5 - 25 V L(+) N(-) ... - Compatibility issues may occur between the HWI-MI module and the HWQS processor. Section 1B: Panel Link Considerations HomeWorks QS ... HomeWorks QS lutron.com _ _ Link

  6. PDF 4 SeriesTM System

    If you need assistance, call the toll-free Lutron Technical Support Center. Please provide exact model number when calling. (800) 523-9466 (U.S.A., Canada and the Caribbean) ... 3 Integral HWI-MI-120 works with HomeWorks Remote Power Modules (RPMs). H-RFP-1P (one RS-232 link) H-RFP-2P (two RS-232 links) HWI-PNL-8-120 HWI-LV32-120. Title ...

  7. Lutron HWI-MI-120 :: Control Interface, Stand-Alone Module for

    Lutron Control Interface, Stand-Alone Module for HomeWorks® Processor Item #: 196212 Cat #: HWI-MI-120 ... Also known as: HWI-MI-120 Specifications Volts AC: 120 Wattage: 2 Volts AC: 120 Wattage: 2 Customer Reviews No reviews for this product (0) ...

  8. Lutron HWI-MI-120 HomeWorks 120V Module Interface to control up to

    Shop Lutron HWI-MI-120 HomeWorks 120V Module Interface to control up to eight Remote Power Modules (RPMs) in a remote power panel enclosure onlinen at Lightingandsupplies.com! Fast shipping on all in-stock products.

  9. HWI-MI-120 newest Rev Hardware and Homeworks hardware compatible?

    91. The HWI-MI-120 datecode is rubber-stamped on the front of the PC board, along the left side. It is under the metal cover, so the PC board must be removed for it to be visible. If the MI datecode is L02 (January 2003) or higher, it will work with HWQS software versions 7.4/8.1 or higher. If it is older, it is not compatible with any HWQS ...

  10. LUTRON Homeworks Interactive HWI-MI-120

    LUTRON HWI-MI-120 . Be the first to review this product . $145.00. Out of stock. SKU. HWI-MI-120. Add to Wish List. Homeworks Interactive model. RPM Wiring Harness is included. Skip to the end of the images gallery . Skip to the beginning of the images gallery . Details

  11. PDF English Figure 2

    HWI-MI-120 HomeWorks ® Module Interface Assembly Input: 120 V 50/60 Hz Typical Power Consumption: 2 W 1. Mount HWI-MI-120 in panel. See Figure 2 for locations. a. For Surface Mounted Enclosures - Use No. 8 nuts and bolts with washers (provided). b. For Recess Mounted Enclosures - Use No. 12 self-tapping screws (provided). WARNING: Shock Hazard ...

  12. Old Homework's interactive

    My HWI-MI -120 processor is located in cabinet Module one and has a manual over switch. I can hit the override switch and every light in the entire house comes on and stays on. When I turn on a circuit with the Sunco led R 30 s The bulbs make a crinkle noise as they heat up then go off after 5 minutes. My garage touchpad circuit has 18 double 4 ...

  13. Lutron HomeWorks Interactive HWI-MI-120 Module Interface with Cable

    Trending at $7.79. Intermatic T104P3 Pool Spa Timer. READ DESCRIPTION. $97.99. Trending at $99.99. Find many great new & used options and get the best deals for Lutron HomeWorks Interactive HWI-MI-120 Module Interface with Cable E416 at the best online prices at eBay! Free shipping for many products!

  14. PDF HWI-PO-120, HWI-PM-120, TM HWI-PO-D48-120, HWI-PM-D48-120 Installation

    The bottom edge of the processor is 3 1/4" (8.25cm) above the bottom wall of the enclosure when it is positioned properly. For HWI-PO-120 or HWI-PO-D48-120 - Install in HWI-PNL-LV32 enclosure in location shown in Figure 2, using the three screws provided with the enclosure. Set processor address.

  15. Lutron HomeWorks Interactive HWI-MI-120 Module Interface with ...

    Taken during a project upgrade, tested and working

  16. PDF HomeWorks Illumination to HomeWorks QS Checklist

    Determine how many HomeWorks QS processors are needed to support all the existing (and new) link types. H48/Q96, HWI keypads, Power Panel, RF, and QS will all require their own links. Panel Link Considerations Lutron recommends replacing all RPM and MI modules built prior to 2003 (Date Code: K53 or older).

  17. Tupolev TU-144

    Crash of a Tupolev TU-144D in Kladkovo: 2 killed. Built by the Voronezh Aircraft Factory, the airplane came out of the plant last April 27. Test flights were conducted on April 27, May 12, 16 and 18. On May 23, the crew completed a fifth test flight from 1111LT and 1307LT without any incidents. At 1730LT, the crew departed Ramenskoye Airport ...

  18. Elektrostal, Moscow Oblast, Russia

    Elektrostal Geography. Geographic Information regarding City of Elektrostal. Elektrostal Geographical coordinates. Latitude: 55.8, Longitude: 38.45. 55° 48′ 0″ North, 38° 27′ 0″ East. Elektrostal Area. 4,951 hectares. 49.51 km² (19.12 sq mi) Elektrostal Altitude.

  19. 5-Section of Moscow Neutron Monitor

    5-Section of Moscow Neutron Monitor. Real time cosmic ray data. Please select desired graphic: Cosmic rays variation. Atmospheric pressure.

  20. PDF 8 SeriesTM H8P5-CE, H8P5-MI-CE, Installation Instructions

    Connect to HomeWorks lighting controls.For H8P5-MI-H48-CE or H8P5-H48-CE models only, connect the ... an HWI-H48-120. If the Dimmer Hub link has a cable length of 15 m (50 ft.) or more, LT-1 link terminators must ... HWI-MI-230 Link Short LED Status LEDs. 5 Figure 6 - Daisy Chained HomeWorks TM Processors LT-1 Link

  21. LUTRON HWI-MI-120 Homeworks and QS Compatible

    LUTRON HWI-MI-120 - QS Compatible. Be the first to review this product . $145.00. In stock. SKU. HWI-MI-120QS. Qty. Add to Cart. Add to Wish List Add to Compare. Newer Model. Works with QS, HW and HWI models. Skip to the end of the images gallery . Skip to the beginning of the images gallery

  22. State Housing Inspectorate of the Moscow Region

    State Housing Inspectorate of the Moscow Region Elektrostal postal code 144009. See Google profile, Hours, Phone, Website and more for this business. 2.0 Cybo Score. Review on Cybo.

  23. LUTRON HWI-MI-120 Homeworks and QS Compatible

    LUTRON HWI-MI-120. Be the first to review this product . $395.00. Out of stock. SKU. HWI-MI-120-NEW. Add to Wish List. New Model/Open Box. Works with QS, HW and HWI models. Skip to the end of the images gallery . Skip to the beginning of the images gallery . Details